Toàn bộ website
Bộ Điều Khiển Sạc Pin Năng Lượng Mặt Trời L60 60A 12 V / 24 V
Bộ Điều Khiển Sạc Pin Năng Lượng Mặt Trời L60 60A 12 V / 24 V
Bộ Điều Khiển Sạc Pin Năng Lượng Mặt Trời L60 60A 12 V / 24 V
Bộ Điều Khiển Sạc Pin Năng Lượng Mặt Trời L60 60A 12 V / 24 V
Bộ Điều Khiển Sạc Pin Năng Lượng Mặt Trời L60 60A 12 V / 24 V
Sản phẩm quốc tế
  • Mã sản phẩm: 1127913 (937 lượt xem)

Bộ Điều Khiển Sạc Pin Năng Lượng Mặt Trời L60 60A 12 V / 24 V

1,836,000đ
  • Màu sắc / Options
    One Size




MÔ TẢ SẢN PHẨM



Description:

This is a three-time controller into the evening(evening)working time,an interval of rest or pause time,Dawn working time(morning light function),the user can according to their needs,set a different time.
A:time(evening working)B:time(Pause working)C:time(dawn working)
 
This is a compatible MPPT charge controller PWM intelligent/efficient/energy saving,he not only has efficient MPPT controller charging function to automatically track the maximum power point,10%-30% higher than the ordinary controller chargingefficiency, also has standby energy saving, more than 30% energy than ordinary controller,the standby power consumption of only 10mA-15mA.
 
Note: It is high quality compatible MPPT + PWM Solar Controllers, not 100% Ture MPPT 

Features:

 
1.Product introduction:
"T"series is an intelligent, multi-purpose solar charge controller.
 
LCD Screen displayBattery reverse discharge protection
Simple(and more time control) operationBattery reverse polarity protection
PWM charing mode+MPPTBattery under voltage protection
Parameter user can resetOverload,short-circuit protection
A key to open and close the loadAutomatic Temperature compensation function
A key to restore the factory settingUSB 5V charge(current 1500mA/1.5A)Optional

2.LCD Operating interface description :




3.Parameter table:

Parameters/ModelMPPT T10MPPT T20MPPT T30MPPT T40MPPT T60MPPT T-0
Maximum Power Current12A20A30A40A60A80A
Installation Lin(mm2)4mm28mm210mm212mm216mm220mm2
Installaton Line(AWG)10#(AWG)8#(AWG)7#(AWG)6#(AWG)4#(AWG)2#(AWG)
Weight280g300g475g500g800g900g
Peak power of solar cell panel (Max Wp)130W260W380W500W800W1000W
Battery capacity configuration100AH200AH300AH400AH600AH800AH
Dimensions143 x 89 x 46(mm)187 x 97 x 61(mm)188 x 128 x 61(mm)
Battery float voltage13.8V(12V system)/27.6V(24V system)
Battery (under voltage) protection10.6V(12V system)/21.2V(24V system)
Battery(under voltage)recovery voltage12.6V(12V system)/25.2V(24V system)
System load loss:<=13mALoop Buck;<=100mV
Operation Temperature :-10°C~60°CStorage Temperature :-30°C~-70°C
Operation Temperature :<=90%,No condensationTemperature compensation :-4mV/Cell/°C
Maximum open circuit voltage of the solar panel18V~24V(12V system) 36V~48V(24V system)
Solar Panel maximum open circuit voltage<=48V

4.Installation 



1.Ready Qi installation tools and materials,and cable. Please matching suitable cable.
2.Ensure that the current desity<4A/mm2 That will help reduce the line pressure drop.check the installation site meets the relevant safety requirements,avoid damp,dusty,flammable,explosive and corrosive gases.
3.Install the controller fixed to the vertical plane,see Section V mounting aperture and hole spacing.In order to ensure a good controller cooling conditions,the controller on the bottom of each reserved 10cm space.
4.As shown on the right wiring sequense:load,battery,solar Battery plate is connected to the controller to be taken to ensure that the load,battery,The polarity of the solar cell panel and controller.
5. Before use:external temperature sensor probe into the left of the controller temperature probe interface probe placed in similar battery temperature.(Line extensive must be build-in devices of the external temperature probe coextensive Otherwise,the controller will control parameters of the temperature compensation of the error.
6.Warning:In order to prevent accidents from occurring,install:non-professionals can not be engaged in loading and unloading operations.

5.Charging Problem Solution:
No proper installation of solar panels cable polarity(“+””-”) Removing the polarity,you  can re-install the correct.
 
More than the rated power of solar panels to reduce solar panel power does not  exceed the rated power controller discharge Problem Solution.
Removing the load is not properly connected to the load,re-install the correct.
More than the rated load power to reduce load power,the controller does not exceed the rated power.
Instantaneous starting current is too large,the battery capacity is too small,the replacement of high-capacity batteries,button troubleshooting.
Wire Cable polarity loose or too square and increase retightening bold cable.
All keys can troubleshoot faults,press 5 seconds to restore factory settings.

Package included:
 
1 x 60A Solar Controller MPPT L60
1 x Temperature Sensor 
1 x English User Manual 

Detail Pictures:








THÔNG SỐ KỸ THUẬT & CHI TIẾT

Thông tin đang cập nhật


HỎI ĐÁP VỀ SẢN PHẨM

Lưu ý: Đối với sản phẩm quốc tế, thông tin và hình ảnh chi tiết chúng tôi đã liệt kê bên trên, có những sản phẩm nhân viên sẽ không tư vấn chi tiết được, mong quý khách vui lòng thông cảm. khi quý khách đặt hàng sẽ có nhân viên gọi điện lại xác nhận đơn hàng và thanh toán.

Vui lòng để đặt câu hỏi, hoặc nếu chưa có tài khoản, bạn có thể đăng ký nhanh.


KHÁCH HÀNG ĐÁNH GIÁ (0 đánh giá)

Vui lòng để bình luận, hoặc nếu chưa có tài khoản, bạn có thể đăng ký nhanh.

Hiện chưa có đánh giá cho sản phẩm, hãy trở thành người đánh giá đầu tiên.

SẢN PHẨM BẠN QUAN TÂM

LÊN ĐẦU TRANG